咨询热线

18964047275

当前位置:首页  >  技术文章  >  深圳龙华观澜大水坑SMC代理 VCHR系列 6.0MPa 直动式减压阀

深圳龙华观澜大水坑SMC代理 VCHR系列 6.0MPa 直动式减压阀

更新时间:2022-10-20      点击次数:401

VCHR 系列 型号列表:

VCA31-5TL-4-02
VCA31-5TL-4-02-F
VCA31-5TL-4-03
VCA31-5TLB-4-02F
VCA31-6G-4-02
VCA31-6G-7-03-F
VCA31A-1G-00-X8
VCA31A-2G-7-02
VCA31A-2G-7-03
VCA31A-2G-7-03F
VCA31A-3G-4-02
VCA31A-3G-4-03
VCA31A-3G-7-03
VCA31A-4D-4-02
VCA31A-4D-4-03
VCA31A-4DLB-4-02
VCA31A-4DLB-4-02F
VCA31A-4DLB-4-03
VCA31A-5D-4-02
VCA31A-5D-4-02-F
VCA31A-5D-4-02F-F
VCA31A-5D-4-02N
VCA31A-5D-7-03
VCA31A-5DB-4-02-F
VCA31A-5DB-7-02F-F
VCA31A-5DL-4-02
VCA31A-5DL-4-02-F
VCA31A-5DL-4-02-F-X15
VCA31A-5DL-4-03-F
VCA31A-5DL-4-03-F-X15
VCA31A-5DL-7-03
VCA31A-5DLB-4-03F
VCA31A-5DLB-4-03-F
VCA31A-5G-4-02
VCA31A-5G-4-02-X15
VCA31A-5G-7-02
VCA31A-5G-7-02F
VCA31A-5G-7-03
VCA31A-5GB-4-03
VCA31A-5T-4-03F
VCA31-YG-4-02-F
VCA35-2DL-4-03
VCA35-4G-4-03
VCA35-4TB-4-03F
VCA35-5C-4-03
VCA35-5D-4-03
VCA35-5D-4-03F-Q
VCA35-5D-7-03
VCA35-5DL-4-03
VCA35-5DL-4-03-X24
VCA35-5DL-4-03-X5
VCA35-5DL-7-03
VCA35-5DLB-4-03
VCA35-5DO-4-03F

气缸的耗气量可以分成最大耗气量和平均耗气量。

最大耗气量是气缸以最大速度运动时所需要的空气浏览,可以表示成:

qr=0.0462D^2*um(P+0.102)

例如缸径D为10cm,最大速度为300mm/s,使用压力为0.6Mpa,则

气缸的最大耗气量qr=0.046*10^2*300*(0.6+0.102)=968.76(L/min),因此选用cv值为1.0或有效截面积为18mm左右的电磁阀即可满足流量要求。

若气缸的使用压力为0.5Mpa,最大速度为200mm/s,则气缸的最大耗气量为qr=553.84。

如果缸径D为50cm,最大速度为300mm/s,使用压力为0.6Mpa,则气缸的最大耗气量为qr=242.19,因此选用cv值选用0.3左右的即可。

最大耗气量=缸径(cm计)平方再乘以系数10(此时使用压力为0.6MPa,最大速度为300mm/s)

 

平均耗气量是气缸在气动系统的一个工作循环周期内所消耗的空气流量。可以表示成:

qca=0.0157(D^2*L+d^2*ld)N(p+0.102)

上式中,

qca:气缸的平均耗气量,L/min(ANR);

N:气缸的工作频率,即每分钟内气缸的往复周数,一个往复为一周,周/min;

L:气缸的行程,cm;

d:换向阀与气缸之间的配管的内径;cm

ld:配管的长度,cm。

例如,缸径D为100mm(10cm)、行程L为100mm(10cm)的气缸,动作频率N为60周/min,d=10mm(1cm),ld=60mm(6cm),

qca=0.0157(D^2*L+d^2*ld)N(p+0.102)=0.0157*(10^2*10+1^2*6))*60*(0.6+0.102)=666.5251704L/min(ANR).

 


联系我们

上海达朋自动化控制设备有限公司 公司地址:上海市松江区久富开发区金马路76号   技术支持:化工仪器网
  • 联系人:达朋自动化
  • QQ:2885421778
  • 公司传真:021-33508692
  • 邮箱:daiweiyun@shdapeng.com

扫一扫 更多精彩

微信二维码

网站二维码